Caught this one today. There are live wires run up through the chimney to access the attic. The chimney is still in use, but only by the 40 gallon gas water heater. I could not see where the flue for the water heater was connected to a b-vent pipe inside the chimney, so I am assuming both are enjoying the same space. Would you call it out for a chimney expert or an electrician? Unless someone has a better idea the electrician will get my vote.
Terry Scroggin
Central IL
www.cei-i.com